Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Rep ; 14(1): 1444, 2024 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-38228773

RESUMO

This paper presents a novel semi-automatic method for lung segmentation in thoracic CT datasets. The fully three-dimensional algorithm is based on a level set representation of an active surface and integrates texture features to improve its robustness. The method's performance is enhanced by the graphics processing unit (GPU) acceleration. The segmentation process starts with a manual initialisation of 2D contours on a few representative slices of the analysed volume. Next, the starting regions for the active surface are generated according to the probability maps of texture features. The active surface is then evolved to give the final segmentation result. The recent implementation employs features based on grey-level co-occurrence matrices and Gabor filters. The algorithm was evaluated on real medical imaging data from the LCTCS 2017 challenge. The results were also compared with the outcomes of other segmentation methods. The proposed approach provided high segmentation accuracy while offering very competitive performance.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Pulmão/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
2.
Med Biol Eng Comput ; 56(3): 515-529, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28825200

RESUMO

Selective internal radiation therapy (SIRT) using Yttrium-90 loaded glass microspheres injected in the hepatic artery is an emerging, minimally invasive therapy of liver cancer. A personalized intervention can lead to high concentration dose in the tumor, while sparing the surrounding parenchyma. We propose a computational model for patient-specific simulation of entire hepatic arterial tree, based on liver, tumors, and arteries segmentation on patient's tomography. Segmentation of hepatic arteries down to a diameter of 0.5 mm is semi-automatically performed on 3D cone-beam CT angiography. The liver and tumors are extracted from CT-scan at portal phase by an active surface method. Once the images are registered through an automatic multimodal registration, extracted data are used to initialize a numerical model simulating liver vascular network. The model creates successive bifurcations from given principal vessels, observing Poiseuille's and matter conservation laws. Simulations provide a coherent reconstruction of global hepatic arterial tree until vessel diameter of 0.05 mm. Microspheres distribution under simple hypotheses is also quantified, depending on injection site. The patient-specific character of this model may allow a personalized numerical approximation of microspheres final distribution, opening the way to clinical optimization of catheter placement for tumor targeting.


Assuntos
Artéria Hepática/efeitos da radiação , Neoplasias Hepáticas/radioterapia , Microesferas , Modelos Biológicos , Angiografia , Automação , Simulação por Computador , Tomografia Computadorizada de Feixe Cônico , Artéria Hepática/diagnóstico por imagem , Artéria Hepática/patologia , Humanos , Processamento de Imagem Assistida por Computador , Fígado/anatomia & histologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Reprodutibilidade dos Testes
3.
Comput Med Imaging Graph ; 55: 13-27, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27553657

RESUMO

The corneal endothelium state is verified on the basis of an in vivo specular microscope image from which the shape and density of cells are exploited for data description. Due to the relatively low image quality resulting from a high magnification of the living, non-stained tissue, both manual and automatic analysis of the data is a challenging task. Although, many automatic or semi-automatic solutions have already been introduced, all of them are prone to inaccuracy. This work presents a comparison of four methods (fully-automated or semi-automated) for endothelial cell segmentation, all of which represent a different approach to cell segmentation; fast robust stochastic watershed (FRSW), KH method, active contours solution (SNAKE), and TOPCON ImageNET. Moreover, an improvement framework is introduced which aims to unify precise cell border location in images pre-processed with differing techniques. Finally, the influence of the selected methods on clinical parameters is examined, both with and without the improvement framework application. The experiments revealed that although the image segmentation approaches differ, the measures calculated for clinical parameters are in high accordance when CV (coefficient of variation), and CVSL (coefficient of variation of cell sides length) are considered. Higher variation was noticed for the H (hexagonality) metric. Utilisation of the improvement framework assured better repeatability of precise endothelial cell border location between the methods while diminishing the dispersion of clinical parameter values calculated for such images. Finally, it was proven statistically that the image processing method applied for endothelial cell analysis does not influence the ability to differentiate between the images using medical parameters.


Assuntos
Algoritmos , Endotélio Corneano/citologia , Endotélio Corneano/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Microscopia/métodos , Forma Celular , Humanos , Reconhecimento Automatizado de Padrão , Processos Estocásticos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...